Surgical, Ophthalmic & Diagnostic Silicone Components

Silicone Intraocular Lens - medical grade silicone product by LSR Injection

Surgical, Ophthalmic & Diagnostic

Surgical and diagnostic silicone parts fail quietly. A seal that tears on the fortieth instrument insertion, a lens that hazes under the slit lamp, a pipette tip that sheds a particle into a sample – none of these show up in a first-article inspection.

We mould components for the sterile field, the eye and the laboratory: wound protectors, trocar seals, intraocular lenses, endoscope accessories and diagnostic parts where the specification is written in tolerances and extractables rather than in appearance.


Request Quote

What we mould for Surgical, Ophthalmic and Diagnostic

Surgical and implantable devices

Parts that enter the sterile field or the body, and the tooling discipline that goes with them.

Diagnostic and laboratory components

Patient-side sensors, sample-contact parts and lab consumables where cleanliness is the product.

Where these devices fail – and how we design around it

1. Particulate shedding in the sterile field

Silicone is soft enough to be forgiving, which also means a poorly finished parting line can shed material every time an instrument passes through a seal. We finish and inspect contact edges rather than relying on the mould alone, and we quantify particulates on the production part for wound protectors and trocar seals instead of quoting a cleanroom class.

2. Trocar seals that lose their seal after repeated insertion

The seal is compressed and wiped hundreds of times in a single procedure. Tear initiation at the aperture is the usual failure path, and it starts at a moulded edge that looked acceptable on the bench. We specify tear strength against the radial expansion of the actual instrument diameter, and validate with insertion cycles on production parts.

3. Optical haze in lenses and transparent covers

Silicone that is transparent in a 2 mm plaque can still haze in a 0.6 mm lens body, because light path length, cure completeness and surface finish all interact. For intraocular lenses and transparent covers we control refractive index, transmission and haze on the finished geometry, and we treat cure time as a specification item rather than a machine setting.

4. Extractables from sample-contact parts

In a diagnostic consumable the part is in contact with the sample or the reagent. Volatile siloxanes and unreacted low-molecular-weight species migrate into the fluid, and the effect appears as drift, false elevation or a failed validation run. Post-cure and extraction profiles are chosen for the contact medium, not for a generic medical grade.

5. Micron-level features that have to assemble

Pipette tips, piston seals and cryotube seals are specified at tolerances where tool wear over 100,000 shots matters as much as the first shot. We build in cavity-level dimensional tracking so a drift is caught on the tool before it becomes a rejected lot.

Material and performance envelope

Typical envelope for surgical, ophthalmic and diagnostic parts – confirm against your device specification.

Property Typical range What it controls
Hardness 30-70 Shore A (seals 40-60 A, optical parts 50-70 A) Sealing force, instrument feel, dimensional stability of thin optical sections
Optical performance Transmission and haze specified on the finished part Usable vision through an IOL or cover; cosmetic defects that are not cosmetic
Tear strength ≥ 25 kN/m on standard test pieces Survival of trocar seals and wound protector rings through repeated use
Dimensional tolerance Typically ±0.05 mm on critical features, tighter on request Assembly with rigid housings, instrument fit, sample volume reproducibility
Post-cure / extraction Volatile and extractable profile matched to contact medium Drift and interference in diagnostic and ophthalmic applications

Regulatory and documentation support

Moulding runs under ISO 13485 in an ISO Class 8 cleanroom, with lot traceability from compound batch to shipped carton. For implantable and ophthalmic programmes we hold the process records that a notified body asks for during a technical file review, including cure verification and environmental monitoring data.

Biocompatibility testing (ISO 10993) is carried out on the production compound and, where the geometry changes the exposed surface area materially, on the finished part. Extractables and leachables work is scoped to the contact medium – saline, reagent, ophthalmic viscosurgical device – rather than run as a generic panel.

Process routes we use

Liquid silicone injection moulding
Thin optical sections and micro-features held to tolerance across multi-cavity tools.
ISO Class 8 cleanroom moulding
Parts that ship sterile-path ready without a post-mould wash.
Prototyping and bridge tooling
Design verification parts in the production compound before capital tooling is committed.

How a programme runs

1. Specification review

We work through the drawing, the contact medium, the sterilisation route and the acceptance tests before quoting, because a tolerance that cannot be measured in production is not a specification.

2. Material and post-cure selection

Compound and cure profile chosen against extractables and optical requirements, not only hardness.

3. Tool build and first article

Cavity-level dimensional report, plus functional testing on the failure mode that matters for the part.

4. Validated serial production

In-process checks, cavity traceability and documented change control before any process change reaches your supply.

FAQ

Can you mould an intraocular lens, or only lens components?

We mould silicone lens bodies with haptics, including the optical surface. Whether the programme is viable depends on the dioptric range and the inspection method you require – send the drawing and we will tell you what we can hold.

What particulate level can you guarantee on a wound protector?

We test the finished part rather than quoting a cleanroom class, because the class describes the room and not the part. The result depends on geometry and finishing, so it is established during validation and then controlled in production.

Do you supply extractables data for diagnostic consumables?

Yes, scoped to the contact medium. A generic panel rarely answers the question a diagnostic manufacturer is actually asking, so we agree the medium and the detection limits first.

How do you control tolerances on a multi-cavity tool?

Each cavity is measured separately and tracked over the tool life, so drift is visible per cavity instead of being averaged out in a lot report.

Can parts be supplied cleanroom-ready without washing?

For many geometries yes – moulding in ISO Class 8 with controlled handling removes the need for a post-mould wash that would itself introduce residue.

What is a realistic lead time for a validated surgical part?

Typically 8-12 weeks from design freeze to validated production for a new tool, of which tooling is about half. Validation scope drives the rest.

Send the drawing, and the test you have to pass

Particulate counts, insertion cycles, haze limits, extractable thresholds – tell us which one your validation stands or falls on. That is the number we design the tool around.